What is it
Key Features
Feature |
Data / Specification |
Measuring principle |
Hydrostatic / Pressure measurement. |
Measuring range |
From 0.1 bar to 10 bar relative pressure, which translates to up to roughly 100 m of water head. |
Accuracy |
Standard ±0.2%, with an optional ±0.1%. |
Temperature range (process medium) |
–10 °C to +100 °C (can tolerate up to +135 °C for short periods in some versions). |
Overpressure / max process pressure |
Up to 40 bar overpressure limit; process pressure rating matches measuring cell. |
Materials (wetted parts / membrane etc.) |
316L stainless steel, Alloy C, optional coatings (e.g. AuPt). Membrane options include gold-rhodium etc. |
Special measuring cell |
“Contite” measuring cell: hermetically sealed, condensate resistant; helps with reliable performance in humid or condensing environments. |
Applications
Communication / Integration
Advantages / What Makes It Good
Limitations / Considerations